Organic SEC (GPC) Columns: General Analysis

KF-800
K-800
KD-800
· Standard organic solvent SEC (GPC) columns
·Supports a wide range of applications from low to high-molecular-weight compounds

*Please refer to Replacement of In-Column Solvent
*Please refet to Solvent-peak Separation Columns for Organic SEC (GPC)
*The columns with 'L' or 'M' at the end of the column name are mixed-gel columns capable of a wide molecular weight distribution range of samples.

(Standard Columns)
KF-800 series shipping solvent : Tetrahydrofuran (THF)
Product code Product name Plate number
(TPN/column)
Exclusion limit
(Polystyrene)
Particle size
(micron)
Size(mm)
ID x Length
GPC KF-801
GPC KF-802
GPC KF-802.5
GPC KF-803
GPC KF-803L
GPC KF-804
GPC KF-804L
GPC KF-805
GPC KF-805L
GPC KF-806
GPC KF-806M
GPC KF-806L
GPC KF-807
GPC KF-807L
GPC KF-G
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 11,000
> 11,000
> 11,000
> 13,000
> 11,000
> 6,000
> 6,000
Guard column
1,500
5,000
20,000
70,000
70,000
400,000
400,000
4,000,000
4,000,000
*(20,000,000)
*(20,000,000)
*(20,000,000)
*(200,000,000)
*(200,000,000)
-
6
6
6
6
6
7
7
10
10
10
10
10
18
18
8
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
4.6 x 10
GPC KF-800D
Solvent-peak separation column -
10
8.0 x 100
*( ): Estimated value
For all products
Recommended flow rate: 0.5 to 1.0mL/min
Max. usable flow rate: 2.0mL/min
Max. usable pressure: 3.5 MPa
Max. usable temperature: 60deg-C

K-800 series shipping solvent : Chloroform
Product code Product name Plate number
(TPN/column)
Exclusion limit
(Polystyrene)
Particle size
(micron)
Size(mm)
ID x Length
GPC K-801
GPC K-802
GPC K-802.5
GPC K-803
GPC K-803L
GPC K-804
GPC K-804L
GPC K-805
GPC K-805L
GPC K-806
GPC K-806M
GPC K-806L
GPC K-807
GPC K-807L
GPC K-G
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 18,000
> 11,000
> 11,000
> 11,000
> 13,000
> 11,000
> 6,000
> 6,000
Guard column
1,500
5,000
20,000
70,000
70,000
400,000
400,000
4,000,000
4,000,000
*(20,000,000)
*(20,000,000)
*(20,000,000)
*(200,000,000)
*(200,000,000)
-
6
6
6
6
6
7
7
10
10
10
10
10
18
18
8
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
4.6 x 10
GPC K-800D
Solvent-peak separation column -
10
8.0 x 100
*( ): Estimated value
For all products
Recommended flow rate: 0.5 to 1.0mL/min
Max. usable flow rate: 2.0mL/min
Max. usable pressure: 3.5 MPa
Max. usable temperature: 60deg-C

KD-800 series shipping solvent : Dimethylformamide (DMF)
Product code Product name Plate number
(TPN/column)
Exclusion limit
(PEG/PEO)
Particle size
(micron)
Size(mm)
ID x Length
GPC KD-801
GPC KD-802
GPC KD-802.5
GPC KD-803
GPC KD-804
GPC KD-805
GPC KD-806
GPC KD-806M
GPC KD-807
GPC KD-G
> 17,000
> 17,000
> 17,000
> 17,000
> 17,000
> 11,000
> 11,000
> 13,000
> 6,000
Guard column
2,500
5,000
20,000
70,000
400,000
4,000,000
*(20,000,000)
*(20,000,000)
*(200,000,000)
-
6
6
6
6
7
10
10
10
18
8
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
4.6 x 10
*( ): Estimated value
For all products
Recommended flow rate: 0.5 to 1.0mL/min
Max. usable flow rate: 1.5mL/min
Max. usable pressure: 3.5 MPa
Max. usable temperature: 60deg-C