Organic SEC (GPC) Columns: General Analysis
KF-800 K-800 KD-800 |
· Standard organic solvent SEC (GPC) columns ·Supports a wide range of applications from low to high-molecular-weight compounds |
*Please refer to Replacement of In-Column Solvent
*Please refet to Solvent-peak Separation Columns for Organic SEC (GPC)
*The columns with ‘L’ or ‘M’ at the end of the column name are mixed-gel columns capable of a wide molecular weight distribution range of samples.
(Standard Columns)
KF-800 series shipping solvent : Tetrahydrofuran (THF)
Product code | Product name | Plate number (TPN/column) |
Exclusion limit (Polystyrene) |
Particle size (micron) |
Size(mm) ID x Length |
---|---|---|---|---|---|
GPC KF-801 GPC KF-802 GPC KF-802.5 GPC KF-803 GPC KF-803L GPC KF-804 GPC KF-804L GPC KF-805 GPC KF-805L GPC KF-806 GPC KF-806M GPC KF-806L GPC KF-807 GPC KF-807L GPC KF-G |
> 18,000 > 18,000 > 18,000 > 18,000 > 18,000 > 18,000 > 18,000 > 11,000 > 11,000 > 11,000 > 13,000 > 11,000 > 6,000 > 6,000 Guard column |
1,500 5,000 20,000 70,000 70,000 400,000 400,000 4,000,000 4,000,000 *(20,000,000) *(20,000,000) *(20,000,000) *(200,000,000) *(200,000,000) – |
6
6 6 6 6 7 7 10 10 10 10 10 18 18 8 |
8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 4.6 x 10 |
|
GPC KF-800D | Solvent-peak separation column | – |
10
|
8.0 x 100 |
*( ): Estimated value
For all products
Recommended flow rate: 0.5 to 1.0mL/min
Max. usable flow rate: 2.0mL/min
Max. usable pressure: 3.5 MPa
Max. usable temperature: 60deg-C
K-800 series shipping solvent : Chloroform
Product code | Product name | Plate number (TPN/column) |
Exclusion limit (Polystyrene) |
Particle size (micron) |
Size(mm) ID x Length |
---|---|---|---|---|---|
GPC K-801 GPC K-802 GPC K-802.5 GPC K-803 GPC K-803L GPC K-804 GPC K-804L GPC K-805 GPC K-805L GPC K-806 GPC K-806M GPC K-806L GPC K-807 GPC K-807L GPC K-G |
> 18,000 > 18,000 > 18,000 > 18,000 > 18,000 > 18,000 > 18,000 > 11,000 > 11,000 > 11,000 > 13,000 > 11,000 > 6,000 > 6,000 Guard column |
1,500 5,000 20,000 70,000 70,000 400,000 400,000 4,000,000 4,000,000 *(20,000,000) *(20,000,000) *(20,000,000) *(200,000,000) *(200,000,000) – |
6
6 6 6 6 7 7 10 10 10 10 10 18 18 8 |
8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 4.6 x 10 |
|
GPC K-800D | Solvent-peak separation column | – |
10
|
8.0 x 100 |
*( ): Estimated value
For all products
Recommended flow rate: 0.5 to 1.0mL/min
Max. usable flow rate: 2.0mL/min
Max. usable pressure: 3.5 MPa
Max. usable temperature: 60deg-C
KD-800 series shipping solvent : Dimethylformamide (DMF)
Product code | Product name | Plate number (TPN/column) |
Exclusion limit (PEG/PEO) |
Particle size (micron) |
Size(mm) ID x Length |
---|---|---|---|---|---|
GPC KD-801 GPC KD-802 GPC KD-802.5 GPC KD-803 GPC KD-804 GPC KD-805 GPC KD-806 GPC KD-806M GPC KD-807 GPC KD-G |
> 17,000 > 17,000 > 17,000 > 17,000 > 17,000 > 11,000 > 11,000 > 13,000 > 6,000 Guard column |
2,500 5,000 20,000 70,000 400,000 4,000,000 *(20,000,000) *(20,000,000) *(200,000,000) – |
6
6 6 6 7 10 10 10 18 8 |
8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 8.0 x 300 4.6 x 10 |
*( ): Estimated value
For all products
Recommended flow rate: 0.5 to 1.0mL/min
Max. usable flow rate: 1.5mL/min
Max. usable pressure: 3.5 MPa
Max. usable temperature: 60deg-C