Refractive Index Detector: Shodex RI-101, 102, 104

The Shodex RI-100 series is a versatile and high sensitive RI detectors that can be used with various manufactures ‘HPLC system’. It consists of a color-LCD, an automatic start-up function, and validation wizard.

NOTICE: WEEE program in EU

(Features)
· Equipped with a color liquid crystal display, the detector monitors s in real time.
· The automatic start-up function controls the complicated operations such asblank substitution and baseline atabilization automatically.
· The validation wizard enables easy component validation.
· Improved temparature control system shortens the required warm-up time and provides stable background.
· The leak sensor automatically stops the pump in case of solvent leakage.
· External input and output terminals and RS232C communication ports can be used to connect various HPLC systems for an advanced automation.

(Specifications)

Product code
Model
RI-101
RI-104
RI-102
Analysis
Semi-micro
Preparative
Flow cell type
2 chanber-type
Measuring method
Deflection type
Reflactive Index range
1.00 to 1.75
Drift*
0.2micro-RIU/h
0.2micro-RIU/h
2micro-RIU/h
Measuring range
0.25 to 512 micro-RIU
0.25 to 512 micro-RIU
2.5 to 5120 micro-RIU
Linearity range
≥600micro-RIU
≥600micro-RIU
≥6000micro-RIU
Noise**
≤2.5nRIU (response: 1.5sec)
≤5nRIU (response: 1.5sec)
≤25nRIU (response: 1.5sec)
Response
0.1 , 0.25 , 0.5 , 1 , 1.5 , 2 , 3 , 6 sec
Auto zero
Full auto zero
Auto zero range
All range
Off-set range
0 to 500mV (Same as integrator output)
Off-set response
10mV (Same as integrator output)
Integrator output
(Sensitivity)
DC 0 to 1V
(2mV/micro-RIU,
8mV/micro-RIU)
DC 0 to 1V
(2mV/micro-RIU,
8mV/micro-RIU)
DC 0 to 1V
(0.2mV/micro-RIU,
0.8mV/micro-RIU)
Cell volume
8micro-L
2.5micro-L
8micro-L
Flow rate (Usual)
0.2 to 3.0mL/min
0.2 to 1.0mL/min
1.0 to 50mL/min
(Max.)
10mL/min (solvent: pure water)
1.0mL/min (solvent: pure water)
100mL/min (solvent: pure water)
Max. back pressure
50kPa
Internal volume
IN to Cell: ca. 60micro-L
Cell to OUT: ca. 600micro-L
All(Cell to OUT: ca.670micro-L
IN to Cell: ca. 10micro-L
Cell to OUT: ca. 355micro-L
All(Cell to OUT: ca.370micro-L
IN to Cell: ca. 120micro-L
Cell to OUT: ca. 510micro-L
All(Cell to OUT: ca.640micro-L
Recorder output
0 to 10mV/FS
EXternal input
Purge On/Off, Auto Zero, Marker
EXternal output
(1) READY (Automatic start-up)
(2) LEAK
(3) ERROR (OVER HEAT/LOW LIGHT INTENSITY/
NULL GLASS HOME POSITION/LOST PARAMETERS/OPTICAL BALANCE)
(Cntact capacity : DC24V 0.1A max.)
Temp. control
OFF, 30 to 50deg-C (1deg-C step), 77deg-C Temp. fuse
Communication port
RS232C
Operational support
functions
(1) Autopamtic start-up (Start Up Sequence), (2) Span/Validation Guide,
(3) Real Time Baseline Monitor
Wetted materials
Stainless steel 316, Teflon, Quartz glass
Powersource,
Power consumption
AC 100 to 240V±10%, 50/60Hz, 150VA max.
Demensions, Weight
W260 x D400 x H200 (mm), ca.13kg
Accessories
Power cable, single code, connector tube, fuse, operation manual

*Pure water 1mL/min, PURGE OFF
**Pure water, response : 1.5sec