VAPLOCK™ Waste Solvent Management

Reduce Leaks Spills and Solvent Vapors

Waste solvent lines from HPLC’s and other analytical instruments should be securely connected to approved waste containers to minimize spills and leaks of solvents and reduce vapor emissions by using Vaplock™ Waste Containment Kits.

Specially designed waste manifolds and special fittings capture the effluent from LC’s and other analytical instruments.

Vapors escaping from waste containers are captured with a high surface area activated charcoal filter.

Manifolds are available for a wide selection of approved waste containers. All disconnect easily from the container without twisting lines. This allows full containers to be conveniently changed without spilling waste solvent.

Organic solvents are expensive and once used, to dispose of. Many procedures allow the capture and reuse of analysis solvents. Recycling Systems isolate pure solvent, uncontaminated with solute, allowing it to be reused.

If your methodology is isocratic, Smart Recycling saves time, expensive solvents and disposal costs. If the analytical methodology uses gradients, those solvents must be captured securely and properly for approved disposal.

We have a manifold and system for your container, your laboratory and your approved disposal system.

Waste Solvent Closed Systems

Vapor Containment

Vapor Lock Reservoir Caps

Special bottle caps, with an integral check valve, prevent solvent vapor from escaping from reservoirs but allow air to enter the bottle for pressure equilibration.

The check valve itself is protected by a filter barrier which also prevents particulates from contaminating your mobile phase.

Color Coded cap kits easily identify your mobile phases.

Color Coded Caps

Vapor Filters with Color Indicators

Solvent vapors, exiting from waste containers, are trapped on the highest capacity charcoal filter available.

A special color indicator tells when the filter needs to be changed. And its response is uniform over a range of organic solvents.

We can evaluate your needs and design the best system for your company, location or laboratory.

Color Indicators

Universal Kits – Make Installation Easy

Manifold Kit

We make waste solvent management easy. Using a waste container of your choice, we have put together kits that will capture waste effluent from most LC’s. Especially Agilent 1100 & 1200’s and Waters’ Alliance or Acuity.

If other comonents are needed, we can provide those as well for a complete solution. We offer a variety of manifolds that fit almost any container you chose.

007-1341: Universal waste solvent collection kit including Multi-Port manifold, hard and soft walled tube connections and line extensions. This kit requires a Justrite container with female PP quick disconnects. Many other kits for other waste containers are available.

007-1163 Fittings Kit for any of our manifolds

007-1407 10-Port Manifold Kit for carboys or Justrite® safety cans

Fittings Kit

Build Your System from the Best Components

MANIFOLDS

Part NumberDescriptionPrice
007-0960 WASTE MANIFOLD, 7-port PP, with PP Quick Disconnect, (6) 1/4-28 & (1) 1/4" NPT port 122.00
007-0962 WASTE MANIFOLD, 7-port PP, with SS/Teflon Quick Disconnect, (6) 1/4-28 & (1) 1/4" NPT port 167.25
007-0443 WASTE MANIFOLD, 6-port PP, with PP Quick Disconnect for Justrite Centura containers, (5) 1/4" NPT ports, (1) 1/2" NPT port 165.50
007-0445 WASTE MANIFOLD, 6-port PP, with SS/Teflon Quick Disconnect for Justrite Centura containers, (5) 1/4" NPT ports, (1) 1/2" NPT port 206.75
007-1123 CARBOY MANIFOLD, 53B, 6-port large bore, with (1) 1/2" FNPT and (5) 1/4" FNPT ports, Polypropylene, free-spinning cap collar 207.25
007-0068 ADAPTER for 1/4" NPT male ports x 1/4-28 female, 9/16" Hex, PP13.20
007-1411 WASTE MANIFOLD, 4-port PP, with Quick Disconnect for Justrite Centura containers, (3) 1/4" NPT ports and (1) 1/2" NPT port. 152.25
007-1248 WASTE MANIFOLD, 10-port PP, with Quick Disconnect for Justrite Centura containers, (6) 1/4-28 ports, (3) 1/4" NPT ports and (1) 1/2" NPT port. 154.75
007-1166 CARBOY MANIFOLD, 83B, 10-port with (1) 1/2" NPT, (3) 1/4" NPT, (6) 1/4-28 ports 250.25

Most of our manifolds are available in completely inert PTFE and SS required in aggressive enviroments like GPC.

KITS with MANIFOLD & FITTINGS

Part NumberDescriptionPrice
007-1407 WASTE MANIFOLD KIT for Justrite container 10-port; PP Manifold, Fittings Kit, Exhaust Filter with adapter, and color breakthrough indicator 317.00
007-1391 WASTE MANIFOLD KIT for GL38 threaded container 10-port; PP Manifold, Fittings Kit, Exhaust Filter with adapter, and color breakthrough indicator 331.50
007-1410 WASTE MANIFOLD KIT for GL45 threaded container 10-port; PP Manifold, Fittings Kit, Exhaust Filter with adapter, and color breakthrough indicator 336.00

VAPOR FILTERS, COLOR INDICATORS & FILTER ADAPTERS

Part NumberDescriptionPrice
007-0332TORGANIC VAPOR FILTERS, Timer, Ultra High capacity, Pk/5200.00
007-0332TIORGANIC VAPOR FILTERS, Timer / Indicator, Ultra High Capacity, Pk/5400.00
007-0629DCOLOR INDICATOR DICS FOR VAPOR FILTERS, Pk/5.237.25
007-0341 FILTER ADAPTER, 1/4" X 1/4" MNPT, PP.1.15
007-1074 FILTER ADAPTER 90 degree, 1/4" X 1/4" MNPT, PP.10.70
007-0342 FILTER ADAPTER, 1/4" X 1/2" MNPT, PP.1.80
007-0351 FILTER ADAPTER 90 degree, 1/4" X 1/2" MNPT, PP.11.60
007-0347 FILTER ADAPTER, 180°, PP/EPDM, w/Justrite Quick Disconnect.36.00
007-0354FILTER ADAPTER, 90°, PP/EPDM, w/Justrite Quick Disconnect47.50

COLOR CODED MOBILE PHASE RESERVOIR CAPS

Part Number DescriptionPrice
007-1419 COLOR CODED caps for reverse phase mobile phases, 4/Kit. 183.00
007-1420 COLOR CODED caps for normal phase mobile phases, 4/Kit. 271.00

Manifolds exist that fit many types of containers. Combined with our fittings kit, installation is fast and easy. Please let us know what you need. Expert help is available for any of these products at any time.

Download the Vaplock Systems PDF